ATOS Servo Valve E-RI-TE-01H. The best deals for ATOS Proportional Hydraulic Valve ATOS Servo Valve E-RI-TE-01H / DK14SC DLKZOR-TE-140-L71 41.
ATOS Servo Valve E-RI-TE-01H. 41/DH04SA, OH08. Typically, the valve will move the spool proportionally to an electrical signal that it receives, indirectly controlling the flow rate. The best deals for ATOS Proportional Hydraulic Valve ATOS Servo Valve E-RI-TE-01H / DK14SC DLKZOR-TE-140-L71 41. Atos servo valve receives pressurized hydraulic fluid from a source, typically a hydraulic pump. It then transfers the fluid to a hydraulic cylinder in a closely controlled manner.
Details:
PIN
|
SIGNAL DESCRIPTION
|
TECHNICAL SPECIFICATIONS |
PIN
|
SIGNAL DESCRIPTION
|
TECHNICAL SPECIFICATIONS | ||
Best Option | Option /IZ | Good Option | Option /IS | ||||
1 | Power supply 24 VDC |
Stabilized: +24 VDC
Filtered and rectified: Vrms 21-33 |
1 | Power supply 24 VDC |
Stabilized: +24 VDC
Filtered and rectified: Vrms 21-33 |
||
2 | Power supply zero | 2 | Power supply zero | ||||
3 | Enable | Enabling normal input working 24 VDC | 3 | Enable | Enabling normal input working 24 VDC | ||
4 | Input + | ± 10 VDC or 0 ÷10 VDC |
4 ÷ 20 mA
|
4 | Input + | ± 10 VDC or 0 ÷10 VDC |
4 ÷ 20 mA
|
5 | Input – | 5 | Input – | ||||
6 | Monitor | ± 10 VDC referred to pin 7 | 4 ÷ 20 mA | 6 | Monitor | ± 10 VDC referred to pin 10 | 4 ÷ 20 mA |
7 |
Signal zero |
Reference 0 VDC | 7 | Signal zero | Reference 0 VDC | ||
8 | Repeat enable | Output enable active | 8 | Coils disabled | Current zero | ||
9 | NC | Not connected | 9 | P & B position | P & B regulation | ||
10 | NC | Not connected | 10 | P & A position | P & A regulation | ||
11 | Fault | functioning = +24 VDC
Alarm = 0 VDC Correct |
11 | Zero position | Zero regulation | ||
PE | Earth | to VDE 0551, CEI 16/6 Connect only when the power supply is not conform | PE | Earth | to VDE 0551,CEI 16/6 Connect only when the power supply is not conform | ||
Proportional valve | origin | Italy |