Relay expansion module MSI-RM2 series Leuze electronic. There has a Leuze MSI-RM2 safety relay module a compact yet cost-efficacious solution. Also, available on stock in Bangladeshi market of current monitoring relay
FEATURES of MSI-RM2 series Leuze electronic:
- For converting electronic safety sensor shutdown signals into potential-free contact signals
- Removable connection terminals to easily change the equipment
The Leuze electronic MSI-RM2 series is a relay expansion module designed for safety applications in industrial automation. Here’s a breakdown of its key features and functionalities:
- Function: Expands the capabilities of safety light curtains, safety laser scanners, and safety switches by providing additional potential-free relay contacts.
- Safety Level: Up to Performance Level PLe according to EN ISO 13849-1, making it suitable for applications requiring high safety integrity.
- Number of Outputs: Two potential-free relay outputs (changeover contacts) for controlling safety-related functions.
- Input: Connects to the safety light curtain, scanner, or switch using a single connection.
- Response Time: Short response time of 10 ms, crucial for fast reaction in safety applications.
- Display: LEDs for status indication of power supply and switching outputs.
- Compact Design: 17.5 mm width allows for space-saving installation in control cabinets.
Applications:
The Leuze electronic MSI-RM2 series relay expansion module is ideal for applications where safety light curtains, scanners, or switches are used to safeguard personnel and equipment. Here are some examples:
- Machine guarding (ensuring personnel safety around moving machinery)
- Material handling systems (preventing accidental access to hazardous areas)
- Robotic work cells (protecting operators and robots from collisions)
Additional Points:
- The MSI-RM2 series is typically used in conjunction with Leuze electronic safety sensors.
- For detailed specifications, wiring diagrams, and compatibility information, refer to the Leuze electronic MSI-RM2 series datasheet, downloadable from their website or through authorized distributors.
- Remember, safety is paramount in industrial automation. Always ensure proper installation and configuration of safety devices according to relevant safety standards and regulations.
I hope this information is helpful!