0.5 KW to 300 KW Three Phase Siemens Variable Frequency Drives VFD.Siemens Inverter, 2.2KW, 440V, 3 Phase Part No: 6SL3210-5BE22-2UV0
Variable frequency drive VFD Siemens SINAMICS V20 – 6SL3210-5BB17-5BV1
Siemens VFD With Panel, Power Size 315kW, Siemens SINAMICS PM240 – 2.2kW 400V 3ph AC Power Module for G120 Series Inverter Drive 6SL3224-0BE22-2AA0.
0.5 KW to 300 KW Input Voltage and Power Ranges (3-phase)
208 V – 240 V, ±10% | 1 to 125 HP (0.75 to 90 kW) |
380 V – 500 V, ±10% | 1.5 to 250 HP (1.1 to 160 kW) |
525 V – 600 V, ±10% | .3 to 200 HP (2.2 to 132 kW) |
Input Frequency | 45 to 66 Hz |
Output Frequency | 0 to 320 Hz |
Frequency Resolution | . 0.01 Hz |
Power Factor | . 0.98 at Nominal Load |
Efficiency | . >97.5% |
Overload Capacity | 1.1 x Nominal Rated Output Current 110% for 1 Minute/10 Minutes |
Peak Overload Capacity | 200% for 2 Seconds Every 20 Seconds |
PWM (Switching) Frequency | |
FS4 to FS6 – 1.5 | 10 kHz Default FS4: 6 kHz; FS5: 4 kHz; FS6 = 4 kHz |
FS7 to FS9 – 1.5. | 6 kHz Default FS7: 4 kHz; FS8: 3 kHz; FS9: 2kHz |
Short Circuit Withstand Rating | 100,000 AIC |
Frequency Reference Analog Input | 0.01 Hz Resolution 0.1% (10-bit) |
Field Weakening Point | 8 to 320 Hz |
Acceleration/Deceleration Time | .0.1 to 3000 sec |
Ambient Operating Temperature | 14°F (-10°C) (no Frost) to 104°F (40°C) up to 122°F (50°C) with Derating |
Storage Temperature | -40ºF (-40ºC) to 158ºF (70ºC) |
Relative Humidity | .0 to 95% RH, Non-condensing, Non-corrosive |
Air Quality | IEC 60068-2-60 (H2S [hydrogen sulfide] and SO2 [sulfur dioxide]) |
Enclosure Class | UL Type 1/IP 21 Standard in Entire HP/kW Range; UL Type 12/IP 54 Options |
0.5 KW to 300 KW Over Voltage Trip Limit
208…240 Vac……………………………….456 Vdc | |
380…500 Vac………………………………..911 Vdc | |
525…600 Vac:…………………………………1094 Vdc |
0.5 KW to 300 KW Three Phase Siemens Under Voltage Trip Limit
208 Vac ………………………………………………………………………. 182.5 Vdc | |
240 Vac ………………………………………………………………………. 210.6 Vdc | |
380 Vac ………………………………………………………………………. 333.5 Vdc | |
480 Vac ………………………………………………………………………. 421.2 Vdc | |
575 Vac ………………………………………………………………………. 504.6 Vdc |
0.5 KW to 300 KW Three Phase Siemens Protection Features
Under-voltage Trip Limit |
Over-voltage Trip Limit |
Ground Fault Protection |
Input (Mains) Supervision |
Motor Phase Supervision |
Over-Current Protection |
Unit Over-temperature Protection |
PLC-HMI Unlock both are very paramount in the Automation industry. All Industrial Automation Machinery components if you require PLC, HMI, VFD, and other components WhatsApp us (+8801712506181). PLC (Programmable Logic Controller) and HMI (Human Machine Interface) to control a machine. For all kinds of brands if you require to crack PLC and HMI feel at liberty to contact us.0.5 KW to 300 KW Three Phase Siemens Variable Frequency Drives VFD
Reviews
There are no reviews yet.