A1SJ71UC24-R4 Mitsubishi Computer-Link Module is at a special price in BD Engineering Solution. Keep contact with us.
Technical data:
Item | Specification | ||||
Interface | RS-422/485 | ||||
Transmission method
|
Dedicated protocol | Half-duplex communication method *one | |||
Bidirectional
|
1: 1 connection |
The full-duplex contact method
|
|||
1: n, m: n connection |
Half-duplex
contact method |
||||
Synchronization system | Start-stop synchronization method | ||||
Transmission speed | start from 300, 600, 1200, 2400, 4800, 9600 to 19200 bps function | ||||
Data format
|
Start bit | One no | |||
Data bit | Seven or Eight |
switch
|
|||
Parity bit | One or none | ||||
Stop bit | One or Two | ||||
Access cycle | One request is performed during the END processing of the sequence program, PLC controller system. | ||||
Error detection
|
Parity check odd/even | ||||
Sum check yes or no | |||||
ER/DR control | No | ||||
DC1/DC3 ,DC2/DC4 control |
Yes or No | ||||
Line configuration
|
Dedicated | 1: 1, 1: n, m: n protocol | |||
No | 1: 1, 1: n | ||||
Bidirectional | 1: 1 | ||||
distance | RS-422/485, distance 500m | ||||
Current consumption | 5VDC 0.1A | ||||
I/O points | 32 points *2 | ||||
Weight | 0.56 (lb) |
A1SJ71UC24-R4 Mitsubishi Computer-Link Module-
CPU | Types of C24 to mount | |
mounted to C24 | A1SJ-71UC24-R4 | A1S-J71C24-R4 |
AnUCPU | A1SJ-71UC24 | AJ7-1C24S3 |
AnACPU | AJ71-C24S3 | |
AnU | the dedicated command is not used. |
Product details:
The A1SJ71(U)C24 computer link module provides a serial connection link to a Mitsubishi. A-Series of PLC Device. BD Engineering can use this module to monitor and control. A Mitsubishi A-Series PLC Device. A1SJ71UC24-R4 article number of computer link giving A1SJ71UC24-R4 to monitor and control device. Speed: 0.3~ 19.2 Kbps function.